Skip to Contents
Schließen

Produkt Support

Erhalten Sie Hilfe für Ihr LG Produkt

Schauen Sie sich die neuesten Informationen zu Ihrem Produkt an

GP55NW40
  • PC Produkte
  • Brenner / Laufwerke
  • GP55NW40

GP55NW40 Handbücher & FAQs

Garantieinformation Arbeit 24 Monate / Ersatzteile 24 Monate Mehr

Software & Firmware

  • Software Update

    Softwareupdates und Treiber sind immer für spezifische Modelle. Prüfen Sie Ihr Handbuch ob es sich um die richtige Software für Ihr Modell handelt.

    New Firmware(ver 1.02) for GP55NW40(only SVC code NW60) Bezug

    [Critical Instructions]


    1. Warnings and Notifications
     
       - Could please check model number which you have.
         If your driver is not the GP55NW40, the firmware is not updated. 

       - Could you please check SVC code on Main Label of GP55NW40 which you have.
         If SVC Code is not "NW60", this firmware is not updated.
      
       - Do not open any programs or start any system functions during the update, 
         as they will interfere with data transfer and damage the drive. 
         Do not cancel the operation once it has been started or the drive will    
         become permanently damaged, as a result.

       - If firmware is not istalled properly as guided below, your drive will be damaged permanently,
         and LG will not be responsible for it.

       - The drives must be original LG branded drives with the external DVD-Writer model number 
         GP55NW40(no OEM units). 

       - If you have an OEM unit, branded with another manufacturers name, 
         Please contact that manufacturer for support and firmware updates.

       - This firmware update is for use only on PC?s with Windows 10, 8/8.1, 7.


    [General Information]

    1.Improvement Point
      
      ? Model : GP55NW40
      ? Version : 1.02
      ? Improvement Point : MS Surface Pro3 Support 


    2.How to update the firmware

     1) Could you please check SVC code on Main Label of GP55NW40 which you have.
        If SVC Code is not "NW60", this firmware is not updated.

     2)Connect the drive at USB port by it self.

     3)Download and unzip the file GP55NW40_SVC code NW60_1.02.ZIP to a folder of your choice. 

     4)Close all other programs including: screen saver, antivirus and/or power-down programs. 
       (If these programs are not closed, they will try to engage the PC, 
       during the update process, thus interrupting the update and damaging the drive).

     5)Check the drive to ensure that there is no disk in the tray before you start 
       the update procedure.

     6)Go into the folder with the update file and double click the GP55NW40_SVC code NW60_1.02.exe 
       program and click the ?update? button (red). Once the update is complete, 
       you will see ?Firmware Update Complete? and the button will become green 
       and advise you to reboot the system. You will need to reboot your PC.



FAQ`s


    • Reparatur
    • Brenner / Laufwerke
    06/20/2013
    Welche PC laufwerke unterstützen M-Disc.
    • Bedienung
    • Brenner / Laufwerke
    06/20/2013
    Welche in Deutschland erhältlichen Laufwerke können M-Disc Medien brennen?
    • Störungssuche
    • Brenner / Laufwerke
    05/09/2016
    Im Gerätemanager erscheint unter XP/Vista/Win7 der Fehlercode 39 oder 19
    • Bedienung
    • Brenner / Laufwerke
    01/21/2016
    Welche Medien werden für den BE14NU40 empfohlen?
    • Bedienung
    • Brenner / Laufwerke
    09/08/2015
    Welche Speichermedien werden für das Modell BH16NS40 empfohlen?