Skip to Contents
Sluiten

Productondersteuning

Verkrijg ondersteuning voor uw LG product

Bekijk de laatste informatie

GSA-4120B
  • Computer producten
  • DVD Branders
  • GSA-4120B

GSA-4120B

Garantie-informatie Arbeidskosten 2 jaar / Onderdelen 2 jaar Meer

Software & Firmware

  • Software Update

    Software upgrades omvatten drivers en firmware updates voor specifieke modellen. Controleer uw gebruikershandleiding om te zien of uw product software updates ondersteund.

    New firmware (ver.A115) for only GSA-4120B(Internal 12X Super Multi DVD Writer) Verwijzing

    [General Information]

    ※ New firmware (ver.A115) for only GSA-4120B(Internal 12X Super Multi DVD Writer)

    ◆ Model:GSA-4120B
    ◆ Ver:A115
    ◆ Improvement Point
    - Improvement of Write Strategy for DVD Media
    => DVD-R: RITEK 8X, MUST 8X, DAXON 8x, INFODISC 8x, KIC 8x
    => DVD+R: OPTODISC 8x, PRODISC 8x, NANYA 8x, IMC 8x, CMC 8x, PRODISC 8x, MCC 12x
    => DVD-RW: PRODISC 4x, CMC 4x, RITEK 4x
    => DVD+RW: MBIPG 4x, DAXON 4x
    - Improvement of DVD+R 12x & DVD+R DL write quality
    - Improvement of DVD±RW rewriting ability

    Refer to the attached file

    ※ INSTRUCIONS

    GSA-4120B Version A115 Firmware Update
    To update the firmware of the GSA-4120B please refer to the following instructions:

    Note: Not following the subsequent update instructions explicitly will result in 
    permanent damage to your drive, for which LG will not be responsible.

    This firmware update is for drives with original firmware versions below A111.
    The drives must be original LG branded drives with the DVD Writer 
    model number GSA-4120B(no OEM units). 

    If you have an OEM unit, branded with another manufacturers name, 
    please contact that manufacturer for support and firmware updates.

    This firmware update is for use only on PC’s with Windows XP, Windows 2000, 
    Windows Millennium Edition (ME), or Windows 98SE.


    [Critical Instructions: (to be followed carefully)

    1. Connect the drive as “master” by it self, on the secondary IDE controller with 
    no other device on the same IDE cable, making note to set the jumper on 
    the back of the drive to the “master” position.

    2. Download the file GSA-4120A115(EW).ZIP to a folder of your choice. 
    This download includes this "Read me(ew)" text file, as well as the GSA4120A115.EXE 
    program, which will auto-update your drive's firmware.

    3. Close all other programs including: screen saver, antivirus and/or power-down programs. 
    (If these programs are not closed, they will try to engage the PC, during the update process, 
    thus interrupting the update and damaging the drive).

    4. Check the drive to ensure that there is no disk in the tray 
    before you start the update procedure.

    5. Go into the folder with the update file and double click the GSA4120A115.EXE program 
    and click the “update” button (red). Once the update is complete, 
    you will see “Firmware Update Complete” and the button will become green 
    and advise you to reboot the system. 

    ※ You will need to reboot your PC
    The update will be complete, after you reboot your system.

    ※ WARNING: 
    Do not open any programs or start any system functions during the update, 
    as they will interfere with data transfer and damage the drive. 
    Do not cancel the operation once it has been started or the drive will 
    become permanently damaged, as a result.