Skip to Contents
Close

Product Support

Receive help on your LG product

Check out the latest software information and tips related to the product.

WP40NB30
  • Computers
  • Burners & Drives
  • WP40NB30

WP40NB30

Warranty Information Labor 90 Days / Parts 1 Year More
If you need Repair Service, submit an online service request. Request a Repair

Manuals & Documents

For the most accurate technical information regarding features, specifications, installation and operation of your LG product, please refer to the Owner's Manual and other documents available for this product.

  • Owner’s Manual
    Owner’s Manual is a basic instruction that contains the product installation and usage.

Software & Firmware

  • Software Update

    Software upgrades include device drivers and firmware updates only for specific models. Check your owner's manual to determine if your product supports software upgrades.

    WP40NB30(SVC code : NB31) new firmware(version:MW03) for Mac OS Reference

    [General information]

    1. General information

    ◆ Model:WP40NB30(Svc code : NB31)
    ◆ Ver:MW03
    ◆ Improvement Point
       -. Improvement of Windows OS install by Boot Camp of Mac PC
          (With MW02 or lower version, in some Mac PC, Windows OS install is failed by using Boot Camp.
           MW03 includes the improvement of this failure.)

    To update the firmware of the WP40NB30(Svc code NB31) for Mac OS. please refer to the following instructions:

    Note: Not following the subsequent update instructions explicitly will result in 
          permanent damage to your drive, for which LG will not be responsible.

          This firmware update is for drives with original firmware versions below MW02
          The drives must be original LG branded drives with the Blu-ray Writer model number 
          WP40NB30(Svc code NB 31)

          If svc code is not NB31, the firmware will not be updated.
          Please check SVC Code on the Main Label. 

          If you have an OEM unit, branded with another manufacturers name, 
          please contact that manufacturer for support and firmware updates.
      
          This firmware update is for use only on PC’s with Mac OS(10.6.4, 10.8.2, 10.9.3)

    2. How to update the firmware

      A. connect the drive at USB port by it self
      B. Please unzip WP40NB30(Svc code NB31)_MW03(Mac).Zip file on Mac OS.
      C. clink  "WP40NB30_MW03.app" file.
      D. Click "Flash it!" button


    [Critical Instructions] (to be followed carefully)

    1. Close all other programs including: screen saver, antivirus and/or power-down programs. 
       (If these programs are not closed, they will try to engage the PC, 
       during the update process, thus interrupting the update and damaging the drive).

    2. Check the drive to ensure that there is no disk in the tray before you start 
       the update procedure.
     
    3. Please never disconnect USB cable while updating firmware.

    4. The update will be complete, after you reboot your system. 
     

     WARNING: Do not open any programs or start any system functions during the update, 
              as they will interfere with data transfer and damage the drive. 
              Do not cancel the operation once it has been started or the drive will 
              become permanently damaged, as a result.



    Thanks.



    WP40NB30(SVC Code : NB31) new firmware(version:MW03) for windows Reference

    [General information]

    ◆ Model:WP40NB30(SVC Code:NB31)
    ◆ Ver:MW03
    ◆ Improvement Point
       -. Improvement of Windows OS install by Boot Camp of Mac PC
        (With MW03 or lower version, in some Mac PC, Windows OS install is failed by using Boot Camp.
         MW03 includes the improvement of this failure.)
       


    To update the firmware of the WP40NB30(SVC Code NB31) please refer to the following instructions:

    Note: Not following the subsequent update instructions explicitly will result in 
    permanent damage to your drive, for which LG will not be responsible.

    This firmware update is for drives with original firmware versions below MW03
    The drives must be original LG branded drives with the Blu-ray Writer model number 
    WP40NB30(SVC Code NB31). 

    If svc code is not NB31, the firmware will not be updated.
    Please check SVC Code on the Main Label. 

    If you have an OEM unit, branded with another manufacturers name, 
    please contact that manufacturer for support and firmware updates.

    This firmware update is for use only on PC’s with Windows 8, 7, Vista, and Windows XP


    [Critical Instructions] (to be followed carefully)

    1. Connect the drive at USB port by it self.

    2. Download the file WP40NB30(SVC Code NB31)_MW03(windows).ZIP to a folder of your choice and unzip the file. 

    3. Close all other programs including: screen saver, antivirus and/or power-down programs. 
       (If these programs are not closed, they will try to engage the PC, 
       during the update process, thus interrupting the update and damaging the drive).

    4. Check the drive to ensure that there is no disk in the tray before you start 
       the update procedure.

    5. Go into the folder with the update file and double click the WP40NB30(SVC Code NB31)_MW03(windows).exe 
    program and click the “update” button (red). Once the update is complete, 
    you will see “Firmware Update Complete” and the button will become green 
    and advise you to reboot the system. You will need to reboot your PC.

    The update will be complete, after you reboot your system. 

    ※ WARNING: Do not open any programs or start any system functions during the update, 
    as they will interfere with data transfer and damage the drive. 
    Do not cancel the operation once it has been started or the drive will 
    become permanently damaged, as a result.

    Thanks.



    WP40NB30 new firmware(version :CW03) for Mac OS. Reference

    [General information]

    1. General information

    ◆ Model:WP40NB30
    ◆ Ver:CW03
    ◆ Improvement Point
       -.Improvement of Windows OS install by Boot Camp of Mac PC
         (With CW02 or lower version, in some Mac PC, Windows OS install is failed by using Boot Camp.
          CW03 includes the improvement of this failure.)

    To update the firmware of the WP40NB30 for Mac OS,please refer to the following instructions:

    Note: Not following the subsequent update instructions explicitly will result in 
    permanent damage to your drive, for which LG will not be responsible.

    This firmware update is for drives with original firmware versions below CW03
    The drives must be original LG branded drives with the Blu-ray Writer model number 
    WP40NB30. 

    If you have an OEM unit, branded with another manufacturers name, 
    please contact that manufacturer for support and firmware updates.

    This firmware update is for use only on PC’s with Mac OS(10.6.4, 10.8.2,10.9.3)

    2. How to update the firmware

      A. connect the drive at USB port by it self
      B. Please unzip WP40NB30_CW03(Mac).Zip file on Mac OS.
      C. clink  "WP40NB30_CW03.app" file.
      D. Click "Flash it!" button


    [Critical Instructions] (to be followed carefully)

    1. Close all other programs including: screen saver, antivirus and/or power-down programs. 
       (If these programs are not closed, they will try to engage the PC, 
       during the update process, thus interrupting the update and damaging the drive).

    2. Check the drive to ensure that there is no disk in the tray before you start 
       the update procedure.
     
    3. Please never disconnect USB cable while updating firmware.

    4. The update will be complete, after you reboot your system. 
     

     WARNING: Do not open any programs or start any system functions during the update, 
              as they will interfere with data transfer and damage the drive. 
              Do not cancel the operation once it has been started or the drive will 
              become permanently damaged, as a result.



    Thanks.



    WP40NB30 new firmware(version : CW03) for windows. Reference

    [General information]

    ◆ Model:WP40NB30
    ◆ Ver:CW03
    ◆ Improvement Point
       -. Improvement of Windows OS install by Boot Camp of Mac PC
          (With CW02 or lower version, in some Mac PC, Windows OS install is failed by using Boot Camp.
           CW03 includes the improvement of this failure.)


    To update the firmware of the WP40NB30 please refer to the following instructions:

    Note: Not following the subsequent update instructions explicitly will result in 
    permanent damage to your drive, for which LG will not be responsible.

    This firmware update is for drives with original firmware versions below CW03
    The drives must be original LG branded drives with the Blu-ray Writer model number 
    WP40NB30(no OEM units). 

    If you have an OEM unit, branded with another manufacturers name, 
    please contact that manufacturer for support and firmware updates.

    This firmware update is for use only on PC’s with Windows 8, 7, Vista.and Windows XP


    [Critical Instructions] (to be followed carefully)

    1. Connect the drive at USB port by it self.

    2. Download and unzip the file WP40NB30_CW03(windows).ZIP to a folder of your choice. 
       
    3. Close all other programs including: screen saver, antivirus and/or power-down programs. 
    (If these programs are not closed, they will try to engage the PC, 
    during the update process, thus interrupting the update and damaging the drive).

    4. Check the drive to ensure that there is no disk in the tray before you start 
    the update procedure.

    5. Go into the folder with the update file and double click the WP40NB30_CW039windows).exe 
    program and click the “update” button (red). Once the update is complete, 
    you will see “Firmware Update Complete” and the button will become green 
    and advise you to reboot the system. You will need to reboot your PC.

    The update will be complete, after you reboot your system. 

    ※ WARNING: Do not open any programs or start any system functions during the update, 
    as they will interfere with data transfer and damage the drive. 
    Do not cancel the operation once it has been started or the drive will 
    become permanently damaged, as a result.

    Thanks.



    WP40NB30(Svc code NB31) new firmware(version MW02) for Mac OS. Reference

    [General information]

    1. General information

    ◆ Model:WP40NB30(Svc code : NB31)
    ◆ Ver:MW02
    ◆ Improvement Point
       -. Mac OS(10.6.4, 10.8.2,10.9.3) support
       -. BD-R M-Disc Support 
       

    To update the firmware of the WP40NB30(Svc code NB31) for Mac OS. please refer to the following instructions:

    Note: Not following the subsequent update instructions explicitly will result in 
          permanent damage to your drive, for which LG will not be responsible.

          This firmware update is for drives with original firmware versions below MW02
          The drives must be original LG branded drives with the Blu-ray Writer model number 
          WP40NB30(Svc code NB 31)

          If svc code is not NB31, the firmware will not be updated.
          Please check SVC Code on the Main Label. 

          If you have an OEM unit, branded with another manufacturers name, 
          please contact that manufacturer for support and firmware updates.
      
          This firmware update is for use only on PC’s with Mac OS(10.6.4, 10.8.2, 10.9.3)

    2. How to update the firmware

      A. connect the drive at USB port by it self
      B. Please unzip WP40NB30(Svc code NB31)_MW02 for Mac.Zip file on Mac OS.
      C. clink  "WP40NB30_MW02.app" file.
      D. Click "Flash it!" button
     


    [Critical Instructions] (to be followed carefully)

    1. Close all other programs including: screen saver, antivirus and/or power-down programs. 
       (If these programs are not closed, they will try to engage the PC, 
       during the update process, thus interrupting the update and damaging the drive).

    2. Check the drive to ensure that there is no disk in the tray before you start 
       the update procedure.
     
    3. Please never disconnect USB cable while updating firmware.

    4. The update will be complete, after you reboot your system. 
     

     WARNING: Do not open any programs or start any system functions during the update, 
              as they will interfere with data transfer and damage the drive. 
              Do not cancel the operation once it has been started or the drive will 
              become permanently damaged, as a result.



    WP40NB30 new firmware(version CW02) for Mac OS. Reference

    [General information]

    1. General information

    ◆ Model:WP40NB30
    ◆ Ver:CW02
    ◆ Improvement Point
       -. Mac OS(10.6.4, 10.8.2,10.9.3) support
       -. BD-R M-Disc Support 
       

    To update the firmware of the WP40NB30 please refer to the following instructions:

    Note: Not following the subsequent update instructions explicitly will result in 
    permanent damage to your drive, for which LG will not be responsible.

    This firmware update is for drives with original firmware versions below CW02
    The drives must be original LG branded drives with the Blu-ray Writer model number 
    WP40NB30. 

    If you have an OEM unit, branded with another manufacturers name, 
    please contact that manufacturer for support and firmware updates.

    This firmware update is for use only on PC’s with Mac OS(10.6.4, 10.8.2,10.9.3)

    2. How to update the firmware

      A. connect the drive at USB port by it self
      B. Please unzip WP40NB30_CW02 for Mac.Zip file on Mac OS.
      C. clink  "WP40NB30_CW02.app" file.
      D. Click "Flash it!" button


    [Critical Instructions] (to be followed carefully)

    1. Close all other programs including: screen saver, antivirus and/or power-down programs. 
       (If these programs are not closed, they will try to engage the PC, 
       during the update process, thus interrupting the update and damaging the drive).

    2. Check the drive to ensure that there is no disk in the tray before you start 
       the update procedure.
     
    3. Please never disconnect USB cable while updating firmware.

    4. The update will be complete, after you reboot your system. 
     

     WARNING: Do not open any programs or start any system functions during the update, 
              as they will interfere with data transfer and damage the drive. 
              Do not cancel the operation once it has been started or the drive will 
              become permanently damaged, as a result.



    WP40NB30(Svc code NB31) new firmware(ver MW02) for windows. Reference

    [General information]

    ◆ Model:WP40NB30(SVC Code:NB31)
    ◆ Ver:MW02
    ◆ Improvement Point
       -. BD-R M-Disc Support 
       


    To update the firmware of the WP40NB30(SVC Code:NB31) please refer to the following instructions:

    Note: Not following the subsequent update instructions explicitly will result in 
    permanent damage to your drive, for which LG will not be responsible.

    This firmware update is for drives with original firmware versions below MW02
    The drives must be original LG branded drives with the Blu-ray Writer model number 
    WP40NB30(SVC Code:NB31). 

    If svc code is not NB31, the firmware will not be updated.
    Please check SVC Code on the Main Label. 

    If you have an OEM unit, branded with another manufacturers name, 
    please contact that manufacturer for support and firmware updates.

    This firmware update is for use only on PC’s with Windows 8, 7, Vista, and Windows XP


    [Critical Instructions] (to be followed carefully)

    1. Connect the drive at USB port by it self.

    2. Download the file WP40NB30(SVC Code:NB31)_MW02.ZIP to a folder of your choice. 
       This download includes this “WP40NB30(SVC Code:NB31)_MW02_Read me(ew)” text file, 
       as well as the WP40NB30(SVC Code:NB31)_MW02.EXE program, which will auto-update your drive's firmware.

    3. Close all other programs including: screen saver, antivirus and/or power-down programs. 
       (If these programs are not closed, they will try to engage the PC, 
       during the update process, thus interrupting the update and damaging the drive).

    4. Check the drive to ensure that there is no disk in the tray before you start 
       the update procedure.

    5. Go into the folder with the update file and double click the WP40NB30(SVC Code:NB31)_MW02.exe 
    program and click the “update” button (red). Once the update is complete, 
    you will see “Firmware Update Complete” and the button will become green 
    and advise you to reboot the system. You will need to reboot your PC.

    The update will be complete, after you reboot your system. 

    ※ WARNING: Do not open any programs or start any system functions during the update, 
    as they will interfere with data transfer and damage the drive. 
    Do not cancel the operation once it has been started or the drive will 
    become permanently damaged, as a result.

    Thanks.



    WP40NB30 new firmware(ver CW02) for windows Reference

    [General information]

    ◆ Model:WP40NB30
    ◆ Ver:CW02
    ◆ Improvement Point
       -. BD-R M-Disc Support 
       


    To update the firmware of the WP40NB30 please refer to the following instructions:

    Note: Not following the subsequent update instructions explicitly will result in 
    permanent damage to your drive, for which LG will not be responsible.

    This firmware update is for drives with original firmware versions below CW02
    The drives must be original LG branded drives with the Blu-ray Writer model number 
    WP40NB30(no OEM units). 

    If you have an OEM unit, branded with another manufacturers name, 
    please contact that manufacturer for support and firmware updates.

    This firmware update is for use only on PC’s with Windows 8, 7, Vista, and Windows XP


    [Critical Instructions] (to be followed carefully)

    1. Connect the drive at USB port by it self.

    2. Download the file WP40NB30_CW02.ZIP to a folder of your choice. 
       This download includes this “WP40NB30_CW02_Read me(ew)” text file, 
       as well as the WP40NB30_CW02.EXE program, which will auto-update your drive's firmware.

    3. Close all other programs including: screen saver, antivirus and/or power-down programs. 
    (If these programs are not closed, they will try to engage the PC, 
    during the update process, thus interrupting the update and damaging the drive).

    4. Check the drive to ensure that there is no disk in the tray before you start 
    the update procedure.

    5. Go into the folder with the update file and double click the WP40NB30_CW02.exe 
    program and click the “update” button (red). Once the update is complete, 
    you will see “Firmware Update Complete” and the button will become green 
    and advise you to reboot the system. You will need to reboot your PC.

    The update will be complete, after you reboot your system. 

    ※ WARNING: Do not open any programs or start any system functions during the update, 
    as they will interfere with data transfer and damage the drive. 
    Do not cancel the operation once it has been started or the drive will 
    become permanently damaged, as a result.

    Thanks.



Video Tutorials

No results were found. Need help? Please try our online Chat , Email , or Call services.

SHOP LG ACCESSORIES

You’ve come to the right place. Find the right accessories and parts for your LG products. Enjoy the reassurance of LG quality and convenience of complimentary shipping when buying directly from LG.com.