* The images and videos above are staged and created for illustrative purposes to enhance understanding. There may be variations depending on the actual product installation.
1) Mosquito Away
- Actual performance may vary depending on usage and environmental conditions.
- University of Ibadan in Nigeria certified the LG Mosquito away technology
- Place of Testing: Peet Grady Chamber
- Test Institution: University of Ibadan in Nigeria
- Test Mosquito: Fifty female mosquitoes (Anopheles, 3~5 days old)
- Test Environment: room size was 35.0m3 (4.46mx4.36mx1.80m) DB (23±1.0)℃, R.H.(36±1.0)%
- Test Method: To count the number of mosquitoes expelled from a testing room where ultrasonic waves are generated by an air conditioner.
- Test Results: Confirmed to expel 92.0% of Anopheles Mosquitoes. (within 24 hours)
- Results may vary depending on the experimental space, temperature, and humidity in the environment.
2) Gen Mode+TM
- At the Step L1 for 12k BTU unit, it is controlled at 0.6kVA.
- The minimum usable kVA value varies depending on the product capacity.
3) Power Mode
- This function can be switched on or off through remote control or ThinQ.
- It continues to operate before the customer deactivates this function.
- TÜV Rheinland Korea confirm that the Power mode of LG air conditioners provides higher cooling speed performance than Jet mode, based on test results in Report No. KR24FSTL 001, which provided a comparison of cooling speeds between the two operation modes of the air conditioner.
Test date: 2024.02.06 ~ 2024.02.07
Location of test: LG air conditioner test chamber
Test institution: TÜV Rheinland
Test models: S4NQ18K23BC, S4UQ18K23BC (Power mode) / S4NQ18K23BB, S4UQ18K23BB (Jet mode)
Test environment: 64.8m³ (6.0m x 4.5m x 2.4m) / Indoor DB (33 ± 0.3)°C, RH (60 ± 5)% / Outdoor DB (35 ± 0.3)°C, RH (60 ± 5)%
Test method: After 2 hours of operation, cooling speed is measured by comparing the temperatures reached in Power mode and Jet mode, respectively.
Test result: Power, the cooling mode of the S4NQ18K23BC and S4UQ18K23BC models, has been verified by TÜV to provide 45% faster cooling performance than Jet mode of the S4NQ18K23BB and S4UQ18K23BB models.
- Depending on installation and usage environment, product performance may vary.
- Excessive cooling operation may increase power usage.
4) Energy Saving
- TÜV has verified that LG Inverter air conditioners (US-Q24K2) save up to 70% more energy than non-inverter LG air conditioners (TS-H2465DAO).
- Test Date: 2016.12, Test room size: 4.3 m * 7.0 m * 2.3 m, Test Conditions: Indoor temperature 33°C, Outdoor temperature 35°C, Relative humidity 60%, Setting temperature 26°C, Test Method: 26.5°C Reach Time Comparison, Test Model: TS-H2465DAO(Conventional) US-Q242Kyo(DUAL Inverter).
5) Fast Cooling
- TÜV has verified that LG Inverter air conditioners (US-Q24K2) cool up to 40% faster than non-inverter air conditioners (TS-H2465DAO).
- Test Date: 2016.12, Test room size: 4.3 m * 7.0 m * 2.3 m, Test Conditions: Indoor temperature 33°C, Outdoor temperature 35°C, Relative humidity 60%, Setting temperature 26°C, Test Method: Measured power consumption during 8hr,
Test Model: TS-H2465DAO(TS-12Y2DA)(Conventional) US-Q242Kyo, US-Q122Kyo.
6) 10-Year warranty on the compressor
- 10-Year warranty on the compressor may vary by product and country, so please check before purchasing.
7) Auto Clean+
- Auto Clean+ automatically initiates the drying function after the cooling operation ends and this is indicated by the remaining residue on the product.
- Auto Clean+ can operate in fan mode for up to 20 minutes automatically, depending on the previous cooling operation usage pattern, to help remove moisture from the heat exchanger.
- The internal drying condition may vary based on the temperature and humidity conditions of the indoor air.
- You can select the airflow strength through LG ThinQ app to add additional airflow during drying time.
- Auto Clean+ is activated upon product shipment and can be used without additional settings.
8) Gold Fin™
- TÜV has verified that the corrosion area of Gold Fin is no more than 0.05% (over RN 9.5)
- Test Date: 2019.06~2020.02
- Test standard : ISO9227:2017, ISO10289:1999, ASTM B 117 Salt Spray Test
- Test sample : Al Fin Sheet (100㎛, 70 X 150㎜) + Organic coating (1.65g/㎡)
- Fitting condition : (35±2)℃, 6.5~7.2 pH, (5±1)% NaCl salt fog spray, 5000h
- Test Result : No more than 0.05% corrosion area ratio. (over RN 9.5)
9) Volt Care
- Test Date : 2025.06~08 LG air conditioner laboratory
- Test Condition : Indoor DB 32℃/WB 23℃, Outdoor DB 48℃/WB 29℃ Setting on cooling mode, This condition was tested by applying high voltage/low voltage (187/276V) to operate the product.
- Test Method : Based on LG testing standards (LG(67)-F0-6037), the outdoor heat exchanger was 30% shielded under the above temperature conditions, and the product was tested for normal continuous operation while changing the voltage and operating modes (4 hours).
- Test Model : S3-Q09AA33Z, S3-Q12JA33Z, S3-Q18KL33Z, S3-Q24K233Z
- Test Result : It was confirmed that all products tested under the proposed test conditions operated normally and continuously.
- The performance result may vary depending on actual usage conditions.
- Continuous operation is possible within the tested voltage range, but the product’s performance may degrade.
10) LG ThinQ
- LG SmartThinQ is now renamed as LG ThinQ.
- Smart features and voice assistant product may vary by country and model. Check your local retailer or LG for service availability.
- Voice-enable smart speaker device is not included.