MULTI V S, Heatpump, 3 Phases, Outdoor Unit, 12HP, R410A

Sufficient Piping Length

Increased piping length allows for flexible design and installation. A cooling system can be implemented more flexibly in a shop, office, reducing work time and providing efficient design.

Dual Sensing Control

Dual Sensing Control senses both humidity and temperature. Also, it controls temperature and amount of air according to the surrounding environment for economical and comfortable operation.

Quick Operating Response

It senses and controls pressure directly using a sensor for faster and more precise response to load variation. The desired temperature can be reached up to 14% faster with pressure control.*

* Results may vary depending on the environment.

All Spec

POWER SUPPLY

  • Case 1 (V, Phase, Hz)

    50 Hz 380-415 V 3N~

  • Limit Range of Voltage(Case 1) (V)

    342~456

  • Case 2 (V, Phase, Hz)

    60 Hz 380 V 3N~

COOLING CAPACITY

  • Rated (kW)

    33.6

  • Rated (Btu/h)

    114700

HEATING CAPACITY

  • Rated (kW)

    37.8

  • Rated (Btu/h)

    129000

POWER INPUT(COOLING)

  • Rated (kW)

    9.08

EFFICIENCY

  • EER(Rated) (W/W)

    3.91

  • COP(Rated) (W/W)

    4.01

POWER FACTOR(COOLING/HEATING)

  • Rated

    0.93/0.93

OUTDOOR FAN

  • Type

    Propeller fan

  • Air Flow Rate(High) (m³/min x No.)

    190

  • Discharge direction(Side / Top)

    Side

OUTDOOR FAN MOTOR

  • Type

    BLDC

  • Drive

    DC INVERTER

  • Output (W x No.)

    250 x 2

COMPRESSOR

  • Type

    Hermetically Sealed Scroll

  • Motor Output (W x No.)

    5,300 x 1

  • Oil Type

    FVC68D(PVE)

HEAT EXCHANGER

  • Fin Type

    Wide Louver Plus

DIMENSIONS

  • Net(W x H x D) (mm)

    1090 x 1625 x 380

  • Shipping(W x H x D) (mm)

    1210 x 500 x 1780

WEIGHT

  • Net (kg)

    155

  • Shipping (kg)

    173

PROTECTION DEVICE

  • High Pressure Prevention

    High pressure sensor / High pressure switch

  • Frost Prevention

    O (Logical)

  • Discharge Tempreature Control

    O (Logical)

  • Compressor/Fan Protection

    Over-heat protection / Over-current protection

  • Inverter Protection

    Over-heat protection / Over-current protection

REFRIGERANT

  • Type

    R410A

  • Precharged Amount (kg)

    6.0

  • Control Type

    Electronic Expansion Valve

CONNECTING PIPE

  • Liquid (mm(inch))

    Φ12.7 (1/2)

  • Gas (mm(inch))

    Φ28.58 (1-1/8)

SOUND PRESSURE LEVEL (OUTDOOR UNIT)

  • Cooling / Heating (dB(A))

    60/60

SOUND POWER LEVEL (OUTDOOR UNIT)

  • Cooling / Heating (dB(A))

    71/71

CONNECTING CABLE

  • Communication Cable(VCTF-SB) (mm² × cores)

    1.0~1.5 x 2

CONNECTABLE INDOOR UNITS NUMBER

  • Max. (Conditional) (EA)

    20