Find helpful information about your LG Product through our Help Library. Find helpful information about your LG Product through our Help Library.

Help library

Find helpful information about your LG product

[LG Air Conditioner Function][Inverter Product] The outdoor unit does not turn off even after reaching the target temperature

Troubleshooting

In case of inverter type air conditioner, the outdoor unit does not turn off even if the indoor temperature reaches the target temperature.

In this power saving method, the minimum amount of electricity is used to adjust the target temperature while making sure the product is not turned off and use less energy to maintain the indoor temperature for reduction of the electricity bills.

In the following cases, the outdoor unit can be turned off.

➔ In case of smaller area size compared to the capacity of the air conditioner

If you select the higher capacity of the air conditioner than the indoor space size, the indoor temperature will go down very quickly and there is danger of overcooling.

➔ In case of raising the target temperature in the middle of operation with less number of rotations after reaching the target temperature

Depending on the indoor temperature, the outdoor unit of the inverter air conditioner can adjust the number of rotations[RPM] for the compressor, thus increasing or decreasing the cooling ability.

If the indoor temperature is much higher than the target temperature, then it requires high cooling performance, thus the number of rotations for the compressor is increased. If it is slightly higher than the indoor temperature, the number of rotations for the compressor is reduced to maintain the less cooling performance.

Inverter control method 1 – When the target temperature is reached, the number of rotations for the compressor/outdoor unit fan is reduced. [Pressure control method]

In this case, the compressor or the outdoor fan does not completely stop but keeps operating at low speed, thus you might feel that [Outdoor unit is on and off or does not operate at all].

Inverter control method 2 – When the target temperature is reached, the number of rotations for the compressor is reduced but that of the /outdoor unit fan is kept same. [Step control method]

In this case, the number of rotations for the compressor is reduced but that of the outdoor fan is not, thus you might feel that [Outdoor unit is on and off or does not operate at all].

※ The outdoor unit is turned off only if the indoor temperature is at least 1℃(32℉) lower than the target temperature.
Due to the inverter characteristics, if the difference between the target temperature and the indoor temperature is small, the number of rotations for the compressor is reduced and thus the target temperature is maintained for power saving effects.

Wait! Find out more.

Is the previously used product a Non-inverter type.

In case of non-inverter product, when the target temperature is reached, the compressor for the outdoor unit is turned off and when there is a difference from the target temperature, it is turned on again to adjust the temperature.
Therefore, it has high power losses and low efficiency.
On the contrary, in case of inverter product, even if the target temperature is reached, instead of completely turning off the compressor, use of necessary energy is varied for lower energy losses.
Inverter product model names
Models with names starting with FNQ~, FQ~, SNQ~, SJQ~ or SQ~

This guide was created for all models, so the images or content may be different from your product.

*Required question