LT1235HNR
10,900/11,200 BTU Cooling Thru-The-Wall Air Conditioner Cooling & Heating
  • 10,900/11,200 BTU Cooling
  • 11,200/9,200 BTU Heating
  • Universal Fit for Sleeve
  • Gold Fin™ Anti-Corrosion
10,900/11,200 BTU Cooling Thru-The-Wall Air Conditioner Cooling & Heating

PERFORMANCE

  • EER
    9.8 / 9.8
    CEER
    9.7/9.7
  • Dehumid. (Pts/Hr)
    3.8
    Dry Air Flow (CFM)
    290
  • dBA Level (Indoor / Outdoor)
    55/62
    Est. Cooling Area (Sq. Ft.)
    550
  • BTU Performance Cooling
    10,900/11,200
    BTU Performance Heating
    11,200/9,200

DIMENSIONS

  • Product (WxHxD)
    24 21/32" x 14 13/32" x 19 21/32"
    Shipping (WxHxD)
    27 23/32" x 18 4/32" x 22 13/32"
  • Net Weight (lbs.)
    87
    Shipping Weight (lbs.)
    97

FEATURES

  • Thermostat Control
    Thermistor
    Air Deflection
    4-Way
  • Auto Restart
    Yes
    Energy Saver Function
    Yes
  • Filter Alarm Function
    Yes
    Fan Speed: Cooling
    2 / 2
  • Fan Only Speed
    2
    Compressor
    Rotary
  • Indoor Fan Type
    Turbo
    Outdoor Vent / Exhaust
    Yes
  • Rear Plastic Mesh Grille Included
    Yes
    Trim Kit Included
    Yes

MATERIALS/FINISHES

  • Available Colors
    White

ELECTRICAL RATINGS

  • Voltage / 60 Hz
    230/208
    Watts (Cooling)
    1,110/1,140
  • Watts (Heating)
    3,500/2,900
    Rated Amps (Cooling)
    5.6/5.2
  • Rated Amps (Heating)
    15.3/14.0

OPTIONAL ACCESSORIES

  • Wall Sleeve
    AXSVA1
    Wall Sleeve with Stamped Aluminum Grille
    AXSVA4
  • Stamped Aluminum Grille
    AXRGALA01

WARRANTY

  • Limited Warranty
    1 Year Parts and Labor
    UPC
    048231376679
ASK & ANSWER

Ask your questions. Share your answers.
Please review the detailed product information and help guides in the
Product Support section for this product prior to posting a question.

I have an LT1235HNR. It is on a single circuit with a 20 amp breaker. The breaker keeps throwing on heat even though I see on the spec sheet that it only should pull about 15 amps on heat. It is about 3 months old and has been on heat without a problem

Asked by: meaux
We regret the trouble you have experienced with this air conditioner. Check to see if there is any other device connected to this circuit which might be placing additional draw on the amperage. If not, then the unit may require service. To make service arrangements, you may either contact our Customer Interactive Center at 800-243-0000, or you can check our Repair Provider Lookup on our website, at http://www.lg.com/us/support/repair/support-repair-provider-lookup.jsp.
Answered by: NeilE
Date published: 2016-04-16

how do I switch this unit LT1235HNR to heat instead of cool?

Asked by: peanutguy
We appreciate your interest in this air conditioner. Press the MODE button repeatedly until the HEAT indicator light is active. The fan is designed to run continuously for this operation.
Answered by: NeilE
Date published: 2016-04-16

Is there an LG specific wall sleeve for this unit?

Is there an LG specific wall sleeve for the LT1235HNR, if so, what is the part number.? Thank you.
Asked by: oinkoink
  • y_2019, m_7, d_14, h_22CST
  • bvseo_bulk, prod_bvqa, vn_bulk_2.0.12
  • cp_1, bvpage1
  • co_hasquestionsanswers, tq_3
  • loc_en_US, sid_MD05185863, prod, sort_[SortEntry(order=LAST_APPROVED_ANSWER_SUBMISSION_TIME, direction=DESCENDING)]
  • clientName_lg
  • bvseo_sdk, java_sdk, bvseo-4.0.0
  • CLOUD, getContent, 185ms
  • QUESTIONS, PRODUCT
Compare (0)