1. No risk of pipe freezing

    Refrigerant pipe robust to cold ensures no potential risk of pipe freezing even during prolonged blackouts.

  2. Remarkable performance in cold

    Wide operation range ensures remarkable heating performance even in an extremely cold weather.

  3. Low noise level

    Noise reduction technology provides quieter and more comfortable experience, increasing installation flexibility in urban areas.

All Spec

SOUND POWER LEVEL (OUTDOOR UNIT)

  • Rated / low noise mode (dB(A))

    60 / 58

SOUND POWER LEVEL (INDOOR UNIT)

  • Rated (dB(A))

    44

SOUND PRESSURE LEVEL AT 5M (OUTDOOR UNIT, CONVERT USING SWL)

  • Rated / low noise mode (dB(A))

    38 / 36

SOUND PRESSURE LEVEL AT 1M (INDOOR UNIT, CONVERT USING SWL)

  • Rated (dB(A))

    36

NOMINAL CAPACITY AND EER (A+35/W+18)

  • Cooling capacity (kW)

    5.50

  • EER

    4.60

NOMINAL CAPACITY AND EER (A+35/W+7)

  • Cooling capacity (kW)

    5.50

  • EER

    2.80

PIPING CONNECTIONS (REF./OUTDOOR UNIT)

  • Gas (mm (inch))

    Ø 15.88 (5/8)

  • Liquid (mm (inch))

    Ø 9.52 (3/8)

  • Length standard / Max. (m)

    5 / 50

  • Level difference Max. (m)

    30

  • Max. length without additional charge (m)

    10

  • Mass of additional ref. charge (g/m)

    40

NOMINAL CAPACITY AND COP (A+7/W+35)

  • COP

    4.90

  • Heating capacity (kW)

    5.50

NOMINAL CAPACITY AND COP (A+2/W+35)

  • COP

    3.52

  • Heating capacity (kW)

    3.30

NOMINAL CAPACITY AND COP (A+7/W+55)

  • COP

    2.70

  • Heating capacity (kW)

    5.50

OPERATION RANGE (OUTDOOR AIR TEMPERATURE)

  • Cooling (Min. ~ Max.) (℃)

    5 ~ 48

  • Heating & DHW (Min. ~ Max.) (℃)

    -25 ~ 35

OPERATION RANGE (LEAVING WATER TEMPERATURE)

  • Cooling (Min. ~ Max.) (℃)

    5 ~ 27

  • Heating (Min. ~ Max.) (℃)

    15 ~ 65

  • DHW (Min. ~ Max.) (℃)

    15 ~ 80

REFRIGERANT

  • GWP

    675

  • Type

    R32

  • Precharged amount (g)

    1,500

SEASONAL EFFICIENCY DATA (HEATING)

  • SCOP (35℃ / 55℃)

    4.65 / 3.23

  • Seasonal space heating eff. class (35℃ / 55℃)

    A+++/A++

  • Seasonal space heating efficiency (ηS) (35℃ / 55℃)

    183 / 126

POWER SUPPLY

  • Voltage, phase, frequency (V, Ø, Hz)

    220-240, 1, 50

PIPING CONNECTIONS (WATER/INDOOR UNIT)

  • Inlet diameter for space heating (inch)

    Male PT 1"

  • Outlet diameter for space heating (inch)

    Male PT 1"

DIMENSION

  • Outdoor unit (W × H × D) (mm)

    950 × 834 × 330

  • Indoor unit (W × H × D) (mm)

    490 × 850 × 315

WEIGHT

  • Outdoor unit (Empty) (kg)

    60.0

  • Indoor unit (Empty) (kg)

    38.1

EXTERIOR

  • Outdoor unit (Color / RAL code)

    Warm gray / RAL 7044

  • Indoor unit (Color / RAL code)

    Noble white / RAL 9016

COMPLIANCE INFORMATION

The safety information for accessories is included with the safety information for the product and is not provided separately.

What people are saying

Find a Store Near You

Experience this product around you.

Our Picks for You