1. No risk of pipe freezing

    Refrigerant pipe robust to cold ensures no potential risk of pipe freezing even during prolonged blackouts.

  2. Remarkable performance in cold

    Wide operation range ensures remarkable heating performance even in an extremely cold weather.

  3. Low noise level

    Noise reduction technology provides quieter and more comfortable experience, increasing installation flexibility in urban areas.

All Spec

SEASONAL EFFICIENCY DATA (HEATING)

  • Seasonal space heating eff. class (35℃ / 55℃)

    A+/A+

  • Seasonal space heating efficiency (ηS) (35℃ / 55℃)

    126 / 117

  • SCOP (35℃ / 55℃)

    3.23 / 3.01f

NOMINAL CAPACITY AND COP (A+7/W+35)

  • Heating capacity (kW)

    16.00

  • COP

    3.27

NOMINAL CAPACITY AND COP (A+2/W+35)

  • Heating capacity (kW)

    16.00

  • COP

    3.25

NOMINAL CAPACITY AND COP (A+7/W+55)

  • Heating capacity (kW)

    14.00

  • COP

    2.78

OPERATION RANGE (OUTDOOR AIR TEMPERATURE)

  • Heating & DHW (Min. ~ Max.) (℃)

    -25 ~ 35

OPERATION RANGE (LEAVING WATER TEMPERATURE)

  • Heating (Min. ~ Max.) (℃)

    25 ~ 80

  • DHW (Min. ~ Max.) (℃)

    25 ~ 80

REFRIGERANT

  • Type

    (ODU) R410A / (IDU) R134a

  • GWP

    (ODU) 2,088 / (IDU) 1,430

  • Precharged amount (g)

    (ODU) 3,800 / (IDU) 1,800

PIPING CONNECTIONS (REF./OUTDOOR UNIT)

  • Gas (mm (inch))

    Ø 15.88 (5/8)

  • Liquid (mm (inch))

    Ø 9.52 (3/8)

  • Length standard / Max. (m)

    7.5 / 50

  • Level difference Max. (m)

    30

  • Max. length without additional charge (m)

    7.5

  • Mass of additional ref. charge (g/m)

    40

PIPING CONNECTIONS (WATER/INDOOR UNIT)

  • Inlet diameter for space heating (inch)

    Male PT 1"

  • Outlet diameter for space heating (inch)

    Male PT 1"

SOUND POWER LEVEL (OUTDOOR UNIT)

  • Rated / low noise mode (dB(A))

    63 / -

SOUND POWER LEVEL (INDOOR UNIT)

  • Rated (dB(A))

    58

SOUND PRESSURE LEVEL AT 5M (OUTDOOR UNIT, CONVERT USING SWL)

  • Rated / low noise mode (dB(A))

    41 / -

SOUND PRESSURE LEVEL AT 1M (INDOOR UNIT, CONVERT USING SWL)

  • Rated (dB(A))

    50

DIMENSION

  • Outdoor unit (W × H × D) (mm)

    950 × 1,380 × 330

  • Indoor unit (W × H × D) (mm)

    520 x 1,080 x 330

WEIGHT

  • Outdoor unit (Empty) (kg)

    89.0

  • Indoor unit (Empty) (kg)

    84.0

EXTERIOR

  • Indoor unit (Color / RAL code)

    Morning gray / RAL 7030

  • Outdoor unit (Color / RAL code)

    Warm gray / RAL 7044

POWER SUPPLY

  • Voltage, phase, frequency (V, Ø, Hz)

    220-240, 1, 50

COMPLIANCE INFORMATION

The safety information for accessories is included with the safety information for the product and is not provided separately.