UHXM Series
Multi Room Split Outdoor Units
  • BLDC (Brushless Direct Current motor) Compressor
  • Optimised Heat Exchanger Path
  • Wide Operating Conditions
  • Improved Grille and Fan
Multi Room Split Outdoor Units
$
Standby Mode

Standby Mode

The Standby Mode operates three minutes after the air conditioner is turned off via the remote control. The Standby Mode removes power from the outdoor unit and only powers the indoor unit remote control receiver circuitry, saving unnecessary power consumption in the outdoor unit.

Quick Operating Response

Quick Operating Response Quick Operating Response
"Night Quiet" Operation

"Night Quiet" Operation


*This function is not user adjustable, please contact your nearest AC installer.
Wide Louver Plus Fin

Wide Louver Plus Fin

Wide Louver Plus fin technology increases 11% of full load heating performance and 6% of COP compared to conventional fin. It can slow down frosting of heat exchanger and postpone the start of defrosting operation.

Compressor

  • Type
    Twin Rotary

Capacity*

  • Cooling - Min/Norm/Max - kW
    1.35/5.27/6.33
    Heating - Min/Norm/Max - kW
    1.41/6.33/7.27

Power Input*

  • Cooling - Min/Norm/Max - A
    0.6/6.0/9.0
    Heating - Min/Norm/Max - A
    0.8/7.0/11.5

EER

  • EER
    4.57

COP

  • COP
    4.15

Airflow Rate

  • Norm - m3/min
    31
    I/S
    517

Sound Pressure

  • Cooling - Norm - dBA
    50
    Heating - Norm - dBA
    52

Dimensions

  • WxHxD - mm
    870×655×320

Net Weight

  • kg
    45.0

Refrigerant

  • Type
    R410A
    Charge - g
    1,700
  • Additional Charge - g/m
    20

Operation Range(Outdoor)

  • Cooling - Min~Max - °C DB
    -10~48
    Heating - Min~Max - °C WB
    -18~18

Power Supply

  • ø/V/Hz
    1/220-240/50

Power Supply Cable

  • No.xmm²
    3C×2.5

Transmission Cable

  • No.xmm²
    4C×0.75

Circuit Breaker

  • A
    20

Piping Length Total

  • m
    50

Piping Length per Branch

  • Max - m
    25

Piping Elevation Difference

  • IDU-ODU - Max -m
    15
    IDU-IDU - Max -m
    7.5

Piping Connection

  • Liquid - mm(inch)×No.
    ø 6.35 (1/4)x3
    Gas - mm(inch)×No.
    ø 9.52 (3/8)x3